Control Boxes & Enclosures
Panels, interface hardware, junction and distribution boxes, and potted or sealed assemblies — the box, the wiring inside it, and the documentation behind it, built as one job.
Quote a Box BuildSend a Panel LayoutBuild review
Drawings, BOM, requirements, and any consigned parts reviewed before work starts — gaps flagged at quote, not delivery.
First article
A first unit built and checked against the documented requirements before the run proceeds.
Build & test
Assembly per spec with inline checks; functional testing to the documented acceptance criteria.
Documentation
Build records and test results delivered with the hardware, quoted to the requirement of the job.
What We Build
Operator interface boxes
Switches, indicators, displays, and connectors mounted and wired to your control scheme.
Junction & distribution boxes
Power and signal distribution with terminal blocks, glands, and labeled wiring.
Potted & sealed modules
Electronics encapsulated in polyurethane potting inside machined or molded housings for moisture, vibration, and harsh environments.
DIN-rail panel builds
Components mounted and wired on rails and back panels to your layout drawing.
Custom housings
Machined aluminum and 3D-printed enclosures when off-the-shelf boxes don't fit the job.
Modified standard enclosures
Off-the-shelf enclosures machined, sealed, and fitted with glands, connectors, and mounting hardware.
Build Details
| Enclosure types | Modified off-the-shelf, machined aluminum, and 3D-printed housings — selected to the environment and budget. |
| Sealing | Gaskets, cable glands, conformal approaches, and full polyurethane encapsulation, designed toward the sealing requirement of the application; formal ingress verification arranged when the program requires it. |
| Wiring | Terminated, routed, strain-relieved, and labeled per spec. |
| Testing | Continuity and functional checks to the documented criteria. |
| Quantities | One-off boxes through pilot and production runs. |
| Documentation | Build records and conformance documentation quoted to the requirement. |
Enclosure Questions
Can you pot our existing board?
Usually — send the board and the environment it has to survive. Encapsulation review covers thermal behavior, serviceability tradeoffs, and connector strategy before anything is committed to potting.
Are your sealed builds IP certified?
Builds are designed and constructed toward the sealing requirement; formal ingress-protection verification is arranged when the program requires certified results.
Do you build one-off boxes?
Yes — single custom boxes for test rigs, retrofits, and field equipment are normal work.
What about serviceability after potting?
Potting is permanent by design. Where service access matters, the design review steers toward gasketed and sealed approaches instead — that judgment call is part of the quote.
Describe the environment. We’ll build the box that survives it.
Most quotes are answered within a few business days.
Request a QuoteControl Boxes & Enclosures
Panels, interface hardware, junction and distribution boxes, and potted or sealed assemblies — the box, the wiring inside it, and the documentation behind it, built as one job.
Quote a Box BuildSend a Panel LayoutBuild review
Drawings, BOM, requirements, and any consigned parts reviewed before work starts — gaps flagged at quote, not delivery.
First article
A first unit built and checked against the documented requirements before the run proceeds.
Build & test
Assembly per spec with inline checks; functional testing to the documented acceptance criteria.
Documentation
Build records and test results delivered with the hardware, quoted to the requirement of the job.
What We Build
Operator interface boxes
Switches, indicators, displays, and connectors mounted and wired to your control scheme.
Junction & distribution boxes
Power and signal distribution with terminal blocks, glands, and labeled wiring.
Potted & sealed modules
Electronics encapsulated in polyurethane potting inside machined or molded housings for moisture, vibration, and harsh environments.
DIN-rail panel builds
Components mounted and wired on rails and back panels to your layout drawing.
Custom housings
Machined aluminum and 3D-printed enclosures when off-the-shelf boxes don't fit the job.
Modified standard enclosures
Off-the-shelf enclosures machined, sealed, and fitted with glands, connectors, and mounting hardware.
Build Details
| Enclosure types | Modified off-the-shelf, machined aluminum, and 3D-printed housings — selected to the environment and budget. |
| Sealing | Gaskets, cable glands, conformal approaches, and full polyurethane encapsulation, designed toward the sealing requirement of the application; formal ingress verification arranged when the program requires it. |
| Wiring | Terminated, routed, strain-relieved, and labeled per spec. |
| Testing | Continuity and functional checks to the documented criteria. |
| Quantities | One-off boxes through pilot and production runs. |
| Documentation | Build records and conformance documentation quoted to the requirement. |
Enclosure Questions
Can you pot our existing board?
Usually — send the board and the environment it has to survive. Encapsulation review covers thermal behavior, serviceability tradeoffs, and connector strategy before anything is committed to potting.
Are your sealed builds IP certified?
Builds are designed and constructed toward the sealing requirement; formal ingress-protection verification is arranged when the program requires certified results.
Do you build one-off boxes?
Yes — single custom boxes for test rigs, retrofits, and field equipment are normal work.
What about serviceability after potting?
Potting is permanent by design. Where service access matters, the design review steers toward gasketed and sealed approaches instead — that judgment call is part of the quote.
Describe the environment. We’ll build the box that survives it.
Most quotes are answered within a few business days.
Request a Quote